Approach about disaster prevention measures of existing elevator

[September 7, 2018]

ID: 9282

Link to social site opens with the other window

About promotion of disaster prevention measures of existing elevator

 By earthquake centering on North Osaka that occurred on June 18, 2018, enclosure occurred in a large number of elevators.
 We receive falling off cases such as elevators in the Great East Japan Earthquake that occurred in enclosure accident and March, 2011 of elevator which occurred in Northwest Chiba earthquake of July, 2005, and technique standards to modify safely such as elevators establishing in Building Standard Act are revised.
 However, control driving device becomes existing impropriety case (we meet standard at the time of setting, but do not meet current standard.) about things of non-setting by elevator installed before it at door open run protector and earthquake.
 It is said that such an elevator is illegal promptly and is not treated, but I would like aggressive correspondence about setting of control driving device at door open run protector and earthquake that owner or manager ensures the security and prevents outbreak of accident.

※ About "elevator and existing impropriety case" (Japan architecture facilities, elevator center) (link to outside site)) (open with window)


Revised summary of technical standard

Government ordinance (the September 28, 2009 enforcement) which revises a part of the Building Standard Act enforcement order

  1. Setting imposition (10 Clause 3 first relations of Article 129 to order) of door open run protector
    Trouble occurs to driving means and controller of elevator and obliges to setting of safety device controlling basket automatically at time when basket went up and down before door of basket and all doorways of climbing road is closed.
    ※ About door open run protector (link "reference materials 2" in Ministry of Land, Infrastructure, Transport and Tourism HP reference)
  2. Setting imposition (10 Clause 3 second relations of Article 129 to order) of earthquake control driving device
    We oblige to setting of safety device deciding that it is possible we detect acceleration such as earthquakes about elevator and let position of door of doorway of climbing road stop basket automatically and to open door of doorway of the basket concerned and door of doorway of climbing road.


Government ordinance (the April 1, 2014 enforcement) which revises a part of the Building Standard Act enforcement order

  1. Preventive measures against falling off of elevator (4 Clause 3 fifth of Article 129 to order and sixth)
    About balance weight of elevator, you shall use structure method that the Minister of Land, Infrastructure and Transport established as thing without fear to fall off by earthquake or other vibration, and, also, check safe thing in structure proof stress for earthquake or other vibration by structural calculation.
  2. Falling off hedge (12 Clause 1 sixth of Article 129 to order) of escalator
    Say that escalator received authorization of thing using structure method that the Minister of Land, Infrastructure and Transport established as thing without fear to fall off by earthquake or other vibration or the Minister of Land, Infrastructure and Transport.